Visit the official COVID-19 government website to stay informed: sacoronavirus.co.za

Building health in the time of Covid-19

How healthy is your building? Do all your staff have masks? Are there hand sanitisers available? Temperature screening? Social distancing protocols? If so, you may think that you have ticked all the hygiene boxes to allow your business to re-open but, have you thought about the drinking water quality?

Water samples to be tested at Waterlab laboratory
Water Samples at Waterlab’s Laboratory

As more businesses open under relaxed lock-down conditions, we may be at risk of an outbreak of another serious respiratory illness: Legionnaires’ Disease. The sudden closure of buildings during the nation-wide lock-down has created an unprecedented decline in water use at these facilities. This low water usage as well as irregular water temperatures may create conditions conducive for the growth of Legionella bacteria, responsible for Legionnaires’ disease. Considering the limited health care resources available to treat respiratory infections due to the Covid-19 pandemic, this disease poses a real risk.

According to Dr Gina Pocock, Microbiologist and Specialist Consultant at Waterlab – a SANAS Accredited Laboratory: “There is a risk of infection wherever water droplets or aerosols can be created, including hot and cold water systems (e.g. showers and taps), cooling towers and evaporative condensers of air conditioners, spa baths, saunas, ornamental fountains, humidified food display cabinets and respiratory therapy equipment.”

At risk businesses therefore include:

  • Hotels, guest houses and restaurants
  • Residential complexes
  • Commercial buildings (air conditioners and gym showers)
  • Industrial companies (cooling towers and air-conditioning)
  • Shipping
  • Schools
  • Sports halls, swimming and leisure pools, spas and saunas
  • Dental practices
  • Hospitals and care homes

Symptoms range from a mild cough and low fever to rapidly progressive pneumonia, delirium (in some cases), coma and death. Most cases, if correctly diagnosed, can be successfully treated with antibiotics, and Legionnaires Disease cannot be spread via human to human contact. The mortality rate in infected individuals ranges between 10 and 20%. There are currently no vaccines to prevent Legionnaires disease, and prior infection does not prevent re-infection.

Globally, Legionella spp. account for 2-5% of community-acquired pneumonia (CAP) cases in adults and is rarely detected in children1,2. However, Legionnaires’ disease is considerably underdiagnosed and underreported. It is estimated that less than 5% of cases are reported to public health authorities through passive surveillance.

Dr Gina Pocock is a specialist microbiologist at Waterlab
Dr Gina Pocock, Specialist Microbiologist at Waterlab

The prevalence of Legionnaires’ disease in South Africa is similarly underestimated. In a survey of pneumonia cases in South Africa from June 2012 through September 2014, Legionella spp. were detected in 21 (1.2%) of 1805 cases3. Hospital-acquired and travel-associated cases of Legionnaires’ disease have also been reported in South Africa. It is very likely that sporadic cases, clusters and even outbreaks occur and are missed. Legionnaires’ disease is a notifiable disease in South Africa, and public health authorities must be notified promptly of any suspected or confirmed cases.

“Water quality monitoring in buildings is proven to help mitigate the risk of Legionella contamination. The proper design, maintenance and temperature of potable water systems are the most important method for preventing the amplification of Legionella,” adds Pocock. “Hot water should be maintained above 60˚C and delivered to taps at temperatures above 50˚C. Coldwater should be maintained below 20˚C. Plumbing systems should be flushed regularly and low flow areas eliminated.”

It is recommended that any commercial facility which has been vacated or underutilised for more than three weeks should test the potable water quality of the facility, as this presents a risk for a Legionnaires’ outbreak, unless the water pipes are properly flushed and sanitised.

In conclusion, there is no known safe level of Legionella in building water systems. Cases of Legionnaires’ disease have been associated with very low levels of Legionella in building water systems4. The intent of a water management programme should be to manage building water systems to reduce the hazardous conditions that allow the Legionella to grow and spread to susceptible people.

With close to 40 years of experience in the industry, Waterlab is a specialist in analytical chemistry, providing services in the various disciplines of water, being potable water supply, sewage treatment, industrial effluents, acid mine drainage or underground water.

References

1. Edelstein PH, Cianciotto NP. Legionella. In: Mandell GL, Bennett JE, Dolin R, eds. Mandell, Douglas, and Bennett’s Principles and Practice of Infectious Diseases. Philadelphia: Elsevier Churchill Livingstone, 2010:2969-84.

2. Mercante JW, Winchell JM. Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations. Clin Microbiol Rev. 2015;28:95-133.

3. Wolter et al., 2016. Legionnaires’ Disease in South Africa, 2012–2014 Emerging Infectious Diseases. 22 (1):131-133.

4. Demirjian A, Lucas CE, Garrison LE, et al., 2015.The importance of clinical surveillance in detecting Legionnaires’ disease outbreaks: a large outbreak in a hospital with a Legionella disinfection system-Pennsylvania, 2011–2012. Clin Infect Dis. 60:1596-602.

Waterlab’s Legionella testing and water risk management services

Waterlab offers peace of mind to organisations returning to work. Specialist consultants and the SANAS accredited laboratory offer a full range of services to help businesses identify, treat and prevent Legionella contamination and, in addition, can sample and test general microbiological quality, which may have deteriorated in standing water reservoirs and stagnant pipelines. Services include:

  • Initial site-specific post-lock-down assessment, sample collection and laboratory analysis
  • Recommendation and supervision of emergency and long-term remedial actions
  • Site-specific management plan based on risk assessment.
  • Risk management planning
  • Scheduled cleaning/flushing programmes
  • Monitoring and record-keeping
  • Defined inspection and microbiological monitoring programme for all on-site water systems
  • Monthly and annual auditing programmes

For further information contact:

Gina Pocock gina@waterlab.co.za or
Leanne Coetzee leanne@waterlab.co.za



Latest


07 Jul 2020
Flatten the curve with Esco, your partner in Biosafety bioprocessing

Esco VacciXcell provides an ideal bioprocessing platform and tools for high cell/product yield at a low cost for various applications…

Flatten the curve with Esco, your partner in Biosafety bioprocessing

Esco VacciXcell provides an ideal bioprocessing platform and tools for high cell/product yield at a low cost for various applications such as vaccines and cell therapy.

06 Jul 2020
Automated Solutions for water and agricultural industries

AMS Alliance offers about 500 methods of analysing different types of water: drinking, waste, surface or sea water. A vast…

Automated Solutions for water and agricultural industries

AMS Alliance offers about 500 methods of analysing different types of water: drinking, waste, surface or sea water. A vast range of agricultural activities such as soil content, fertilisers, plants, tobacco, cereals, etc., can also be analysed.

17 Jun 2020
Afrox achieves Level 1 status under SA’S B-BBEE regulations

African Oxygen Limited (Afrox) has achieved Level 1 status under South Africa’s Broad-Based Black Economic Empowerment regulations.

Afrox achieves Level 1 status under SA’S B-BBEE regulations

African Oxygen Limited (Afrox) has achieved Level 1 status under South Africa’s Broad-Based Black Economic Empowerment regulations.

15 Jun 2020
Innovative pump technology offers operational and water savings to mines

As at the end of 2019, mining production had faced significant losses for two consecutive years, with production levels 1.3% lower…

Innovative pump technology offers operational and water savings to mines

As at the end of 2019, mining production had faced significant losses for two consecutive years, with production levels 1.3% lower in 2019, which was also 2.1% lower than in 2017. And the reality is that production levels will likely be lower still for 2020 due to the unprecedented times faced…


Top stories


10 Mar 2020
Treating wastewater with ozone could convert pharmaceuticals into toxic compounds

With water scarcity intensifying, wastewater treatment and reuse are gaining popularity. But some methods for killing microbes in wastewater create…

Treating wastewater with ozone could convert pharmaceuticals into toxic compounds

With water scarcity intensifying, wastewater treatment and reuse are gaining popularity. But some methods for killing microbes in wastewater create disinfection byproducts (DBPs) that could be harmful to human health. Now researchers have found that ozone treatment and subsequent chlorination can convert trace amounts of some pharmaceuticals in wastewater into…

09 Mar 2020
Using the PMB’s heat settings for efficient sample drying

Loss on drying is a key testing method for laboratories, from bacterial biomass determination to pharmaceutical testing, environmental analysis and…

Using the PMB’s heat settings for efficient sample drying

Loss on drying is a key testing method for laboratories, from bacterial biomass determination to pharmaceutical testing, environmental analysis and quality testing. Adam Equipment’s PMB moisture analyser features three drying modes that can be set to start as soon as the PMB’s lid is closed. The PMB allows users to…

06 Mar 2020
Containment and pharmaceutical HVAC validation training

ALPA (Air & Lab Products Africa) recently co-hosted an in-depth training session together with Air Techniques International. Presented by Tim…

Containment and pharmaceutical HVAC validation training

ALPA (Air & Lab Products Africa) recently co-hosted an in-depth training session together with Air Techniques International. Presented by Tim Triggs, EMEA Regional Director – Air Techniques International, who flew to South Africa specifically to present the courses on containment and pharmaceutical HVAC validation training, the four courses focussed on:…

04 May 2020
Pfeiffer Vacuum showcases Hena 50 and Hena 70 powerful vacuum pumps for mass spectrometer systems

Air and Vacuum Technologies represent Pfeiffer Vacuum in South Africa and supply Hena 50 and 70 vacuum pumps.

Pfeiffer Vacuum showcases Hena 50 and Hena 70 powerful vacuum pumps for mass spectrometer systems

Air and Vacuum Technologies represent Pfeiffer Vacuum in South Africa and supply Hena 50 and 70 vacuum pumps.